Additional Information |
|
| Average Filter Life: |
|
Pre-Filter 6-18 months Sleeves 2-3 years Cartridges 6-12 months (filter life is dependant on the operating environment) |
|
| Filter Configuration: |
|
1 (set of 4) - Post-Filter Sleeve (F3) 1 - Pre-Filter (HEPA type) - (F1) 1 (set of 4) - Gas Cartridge (F2) |
|
| Product Dimensions: |
|
H 28 inches x W 15 inches x D 16 inches |
|
| Information: |
|
The IQAir ® GC ™ Series is a specialized line of advanced air cleaning devices that meets almost any gas phase removal need in residential or commercial environments. Each model has a specialized gas phase media configuration. They have nearly half the media as the GCX ™ Series units. |
|
| Other Information: |
|
Customized Gas and Odor Control
The IQAir GC AM is compact and customized for specific gaseous contaminants and odors. Just like a professional gas mask, IQAir maximizes filter efficiency for different gases and odors by offering the right filter cartridge. And while gas and odor control is a particular strength of these systems, the GC ™ Series also offers excellent filtration efficiency for particles.
Gas Cartridge Technology
The IQAir GC AM uses four reusable filter cartridges to hold up to 12 lbs. of gas phase media. The cylindrical shape of these cartridges allows for optimum contact between the air and gas phase media, which ensure high removal efficiencies. The large surface area of the cartridges enables high air flow rates. Since IQAir gas filter cartridges are reusable, replacing them is not only economical, but also environmentally friendly.
High-Efficiency Particulate Filtration
The particulate filtration GC units complements the gaseous filtration process by removing over 97 percent of particles before they can reach the gas phase media. This increases the efficiency and life of the media by preventing its pores from clogging. The GC units' overall filtration efficiency for particles is 97 percent at .3 microns. The post filter is electrostatically charged to trap particulate pollutants and microorganisms (bacteria and viruses) |
|
| Applications: |
|
* Chemical control * Control of the following: Benzene, Butane, Carbon tetrachloride, Chlorine, Chloroform, Chloropicrin, Cyclohexane, 1.1 Dichloroethane, Ethylene oxide, Freon 11, Indole, Methyl chloride, Methyl chloroform, Methylene chloride, Nitrobenzene, Phosgene, Pyridine, Sulfuric acid, Toluene, Xylene |
|
| Suggestions: |
|
For more critical filtration of microbiological contaminants, bacteria, and viruses see our Cleanroom H13 ™ or our Dental Series models. |
|
| Included: |
|
All systems come complete with filters, remote control, batteries (for remote control) owners manual, user guide video (both VHS and DVD), set of 4 casters, 10 foot power cord, and certificate of guaranteed performance. |
|
| Specifications: |
|
1. User Control Panel 2. Carrying Handle 3. No-Draft Diffuser 4. Particle Post-Filter Sleeves 5. Gas and Odor Filter Cartridges 6. Snap-Open Locking Arms 7. High-Performance Centrifugal Fan 8. Advanced Fan Control 9. Pre-Max Pre-Filter (Class H11) 10. Dual Floor Air Intake |
|
| Warranty: |
|
1 year on unit including fan motor, excluding filters |
|
| Notes: |
|
The IQAir GC VOC uses four reusable filter cartridges to hold up to 12 lbs. of gas phase media. The cylindrical shape of these cartridges allows for optimum contact between the air and gas phase media, which ensure high removal efficiencies. The large surface area of the cartridges enables high air flow rates. Since IQAir gas filter cartridges are reusable, replacing them is not only economical, but also environmentally friendly.
Chemical Control of the following: Benzene, Butane, Carbon tetrachloride, Chlorine, Chloroform, Chloropicrin, Cyclohexane, 1.1 Dichloroethane, Ethylene oxide, Freon 11, Indole, Methyl chloride, Methyl chloroform, Methylene chloride, Nitrobenzene, Phosgene, Pyridine, Sulfuric acid, Toluene, Xylene |
|
| Number of Fan Speeds: |
|
6 |
|
| Air Delivery (with new filters installed) per Speed: |
|
1 - 35 cfm 2 - 60 cfm 3 - 95 cfm 4 - 125 cfm 5 - 150 cfm 6 - 235 cfm |
|
| Maximum Coverage Area: |
|
900 sq ft (based on maximum fan speed and an 8.5 ft ceiling) |
|
| Net Weight (including filters): |
|
51 lbs |
|
| System Efficiency for Particles: |
|
99 percent or more for 0.3 microns 99 percent for total particle count |
|
| Power Requirements: |
|
120 V, 215 Watts, 50-60 Hz. The entire electrical system is UL certified. |
|
| Energy Consumption (Max): |
|
215 W |
|
| Power Cable: |
|
Grounded Detachable 10 foot |
|
| Number of Filter Stages: |
|
3 (particle pre-filtration, gas absorption and particle post-filtration) |
|
| Pre-Filter Efficiency: |
|
98 percent at 0.3 microns |
|
| Pre-Filter Frame Material: |
|
Mini-pleat HEPA filter |
|
| Gas Cartridge Frame Material: |
|
Disposable Cylinders |
|
| Gas Phase Filter: |
|
Approx. 11 - 13 lbs of impregnated activated carbon. |
|
| Post Filter Sleeve: |
|
Four electrostatically charged 98 percent at 0.3 microns fiber media sleeves |
|
| Number of Housing Modules: |
|
7 |
|